August 12, 2011: Wake up 6AM. Pack voltage from yesterday’s Portland trip was 150.2; 60% state of charge. Started charging at 6:AM at 28AMPs. The cooler morning of 55 degrees F was good for PFC 30 charger. The current was able to stay higher. Started charging at 6:30AM at 28 Amps for 1 hour and 25 minutes to 171V. Charge finished at 7:55AM. Regulator#1, #2 and #3 reached the 14.50V first.
NEXT: Set all limits on newly installed regulators and install final replacement regulator that should have arrived yesterday.